<p id="ysocz"><label id="ysocz"></label></p>
        1. <nav id="ysocz"></nav>
          中文字幕人妻有码久视频,亚洲www永久成人网站,亚洲高潮喷水无码AV电影,亚洲欧洲日产国码无码网站,扒开双腿猛进入喷水高潮叫声,亚洲 欧美 唯美 国产 伦 综合,99热这里有精品,日本激情久久精品人妻热
          Main Products:Electromagnetic Flow meter  Metal Tube Flow Meter  Glass Tube flow Meter
           
           
           
           
           
          Glass Tube Flowmeter
          LZB/LZJ series glass rot...
          Glass Tube Flowmeter
          Glass Tube Flowmeter
          LZB-()W/WB series micro ...
          Glass Tube Flowmeter

           


          LDG series PTFE lining electromagnetic flowmeter high anti-corrosion [CHENGFENG FLOWMETER] stainless steel electrode 4-20mA out put flange/clamp/plug-in connection
          Product Model:LDG series

          CHENGFENG FLOWMETER from factory has been committed to flow meter for decades and the research and development and production of the material level meter, over the years, we sell not only products, but also a kind of attitude and service, pay attention to is the feeling of the customer experience, from the perspective of customers, strive to achieve consistent perfect pre-sale and after-sale!

          Summary

          The electromagnetic flowmeter is composed of two parts by electromagnetic flow sensor and electromagnetic flow converter.The operation of an electromagnetic flowmeter is based on Faraday law of electromagnetic induction.The mainly parts of the sensor are: measuring tube,electrode poles,excitation coil,iron core,yoke and housing. The measuring tube of the sensor is a short alloy tube whose diameter is D, the inner surface of it has an insulating liner.Two electrodes are fixed in the measuring tube along with the diameter direction of it and they usually flush with the inner surface liner.When excitation coil pulsed by two-way square wave,there generates a working magnetic field with a flux density B in the vertical direction of the measurement axis.In the meantime,if some electrical conductivity liquid flows at an average velocity V through the measuring tube ,cuts lines of the magnetic field,there generates induced electromotive force E.Electromotive force E is directly proportional to the product of flux density B、measuring tube diameter D and average velocity V,that's: E BVD. Electromotive force E(flow signal) is measured by the electrodes and transmitted to transducer through cable.After the transducer handles the flow signal by magnifying it, the flow and total amount can be displayed,also will output pulse and analog current etc.


          Main technical parameters

           

          Technical parameters of whole flowmeter and sensor


          Chart 1

          Carried Standard

          ANSI/DIN/JIS

          DN

          3.6.10.15.20.25.32.40.50.65.80.100.125.150.200.250.300.350.400.450.500.
          600.700.800.900.1000.1200.1400.1600.1800.2000.2200.2400.2600.2800.3000

          Max.Flow Velocity

          15m/s

          Accuracy

          ±0.5% of indicating value(flow velocity 0.8m/s); ±4mm/s(flow velocity<0.8m/s )

          Fluid Conductivity

          ≥5uS/cm

          Nominal Pressure

          4.0MPa

          1.6MPa

          1.0MPa

          0.6MPa

          6.3,10MPa etc.

          DN3~DN150

          DN15~DN600

          DN200~DN1000

          DN700~DN3000

          Special Ordering

          Lining Material

          PTFE,Poly neoprene,Polyurethane,F46,PFA with net

           

          Sensor

          -25 deg.C~+60 deg.C

          Convertor and integrated type

          -10 deg.C~+60 deg.C

          Fluid Max.Temperature

          Integrated type

          70 deg.C

          Separated type

          Poly Neoprene Lining

          80 deg.C;120 deg.C(notes in order)

          Polyurethane Lining

          80 deg.C

          PTFE Lining

          100 deg.C;150 deg.C(notes in order)

          FEP Teflon

          PFA with net

          Material of signal electrode and ground electrode

          SS316L,HastelloyB,HastelloyC,Ti,Ta,Platinum-iridium alloy,Stainless steel coating with tungsten carbide

          Electrode drawknife apparatus

          DN80~DN3000

          Connection flange material

          Carbon steel

          Connection ring material

          Stainless steel1Cr18Ni9Ti

          Enclosure protection

          ND15~DN3000 separated sensor with rubber or PU lining

          IP65 or IP68

          Integrated(rounded converter)

          IP65

          Other sensors and separated converter

          IP65

          Explosion proof sensor and converter

          IP65

          Spacing(separated type)

          Normally the separation distance between converter and sensor is less than 100m,if more please order specially.(Note: our company provide 10m length standardly,if need more, please indicate the length in order, and the cost will be add more)

          Output of analog current

          0~10mA     load resistance 0~1.5Ω

          4~20mA     load resistance 0~750Ω

          Frenquency output

          1~5000Hz

          Pulse output

          Separated type output by two way: forward and reverse flow; integrated type output one way

          Frenquency range:0~5KHz,uper limit 1~5 optionally

          Square wave or pulse with 25ms pulse width

          Transistor switch output with isolation protection,can absorb 250mA current and withstanding 35V voltage

          Two-path alarm output

          Alarmable(programable)high/low flow,blank pipe,fault condition,forward and reverse flow,simulation volume exceeds range,pulse volume exceeds range,disconnect pulse small signal

          Transistor switch output with isolation protection,can absorb 250mA current and withstanding 35V voltage(Not isolated with pulse output)

          Digital communications

          RS232,RS485,HART(add specially)

          Explosion proof mark

          Integration ExdeiaⅡCT4

          Separated Exd[ia] ⅡCT4(converter)     ExdeiaⅡCT4(sensor)

          [Type Selection]

          CHENGFENG FLOWMETER intelligent electromagnetic flowmeter is based on a standard manufacturing system and development, its advanced design concepts to ensure the high precision and high reliability of the product, compared with the old electromagnetic flowmeter, it has high measurement precision, high reliability, good stability, complete function, long life and other advantages.

           

           

           

           

          CHENGFENG FLOWMETER  for flowmeter market customer demand, carry on the improvement of professional products, technology research and development, and strive to make customer satisfaction of the flowmeter.CHENGFENG FLOWMETER  variety, style complete, direct manufacturers, quality assurance, affordable, welcome customers to come to consult, the choose and buy.Changzhou into feng help selection, solve your doubt flowmeter.



          ? 2012 Changzhou Chengfeng Flowmeter Co.,Ltd All Rights Reserved   Main Products:Electromagnetic Flow meter  Metal Tube Flow Meter  Glass Tube flow Meter
          Design by Lingdong Internet  Switchboard:86-519-85503558,86-519-85503688  Fax:86-519-85505269,86-519-85503588-8008
          Friendly Links:成豐儀表阿里巴巴店鋪    新浪    
          主站蜘蛛池模板: 日韩毛片在线视频x| 欧美国产精品不卡在线观看| 久久亚洲日本激情战少妇| 乐活家庭迅雷| 爆乳2把你榨干哦ova在线观看| 免费av在线播放观看| 三级片视频网站| 天天澡日日澡狠狠欧美老妇| 亚洲男人天堂2018| 欧美日本精品一本二本三区| 狠狠A狠狠A| 开心五月婷婷伊人久久| 国产成人无码aa片免费看| 久久综合久中文字幕青草| 蜜臂AV| 【_undefined?-?P站免费版?-?永久免费的福利视频平台】 | 特级毛片a级毛片在线播放www| 一木色道久久久蜜桃| 996免费视频国产在线播放| 日韩精品国产专区一区| 99久久99久久精品国产片| 99网友自拍视频在线| 国产精品国三级国产av| 亚洲香蕉av一区二区蜜桃| 亚洲中文字幕日韩精品| 美女视频在线永久免费观看| 最新2021精品视频自拍| 果冻传媒18禁免费视频 | 国产成熟妇女性视频电影| 厨房与子乱在线观看| 日本一区二区不卡在线| 亚洲一区二区欧美色妞影院 | 亚洲AV无码专区首页第一页| 亚洲AV无码久久精品色欲| 1769国内精品视频在线播放 | 伊人久久大香线蕉AV网| 亚洲男人天堂网| 国产成人无码AV片在线观看不卡| 五月综合激情久久婷婷| 日本人妻巨大乳挤奶水免费| 国产视频9999|