          Main Products:Electromagnetic Flow meter  Metal Tube Flow Meter  Glass Tube flow Meter
           
           
           
           
           
          Glass Tube Flowmeter
          LZB/LZJ series glass rot...
          Glass Tube Flowmeter
          Glass Tube Flowmeter
          LZB-()W/WB series micro ...
          Glass Tube Flowmeter

           


          LDG series high anti-corrosion electromagnetic flowmeter PTFE lining [CHENGFENG FLOWMETER] 4-20mA out put stainless steel electrode sewage treatment
          Product Model:LDG series
          CHENGFENG FLOWMETER intelligent electromagnetic flowmeter is based on a standard manufacturing system and development, its advanced design concepts to ensure the high precision and high reliability of the product, compared with the old electromagnetic flowmeter, it has high measurement precision, high reliability, good stability, complete function, long life and other advantages.

          Summary

          The electromagnetic flowmeter is composed of two parts by electromagnetic flow sensor and electromagnetic flow converter.The operation of an electromagnetic flowmeter is based on Faraday law of electromagnetic induction.The mainly parts of the sensor are: measuring tube,electrode poles,excitation coil,iron core,yoke and housing. The measuring tube of the sensor is a short alloy tube whose diameter is D, the inner surface of it has an insulating liner.Two electrodes are fixed in the measuring tube along with the diameter direction of it and they usually flush with the inner surface liner.When excitation coil pulsed by two-way square wave,there generates a working magnetic field with a flux density B in the vertical direction of the measurement axis.In the meantime,if some electrical conductivity liquid flows at an average velocity V through the measuring tube ,cuts lines of the magnetic field,there generates induced electromotive force E.Electromotive force E is directly proportional to the product of flux density B、measuring tube diameter D and average velocity V,that's: E BVD. Electromotive force E(flow signal) is measured by the electrodes and transmitted to transducer through cable.After the transducer handles the flow signal by magnifying it, the flow and total amount can be displayed,also will output pulse and analog current etc.


          Main technical parameters

           

          Technical parameters of whole flowmeter and sensor


          Chart 1

          Carried Standard

          ANSI/DIN/JIS

          DN

          3.6.10.15.20.25.32.40.50.65.80.100.125.150.200.250.300.350.400.450.500.
          600.700.800.900.1000.1200.1400.1600.1800.2000.2200.2400.2600.2800.3000

          Max.Flow Velocity

          15m/s

          Accuracy

          ±0.5% of indicating value(flow velocity 0.8m/s); ±4mm/s(flow velocity<0.8m/s )

          Fluid Conductivity

          ≥5uS/cm

          Nominal Pressure

          4.0MPa

          1.6MPa

          1.0MPa

          0.6MPa

          6.3,10MPa etc.

          DN3~DN150

          DN15~DN600

          DN200~DN1000

          DN700~DN3000

          Special Ordering

          Lining Material

          PTFE,Poly neoprene,Polyurethane,F46,PFA with net

           

          Sensor

          -25 deg.C~+60 deg.C

          Convertor and integrated type

          -10 deg.C~+60 deg.C

          Fluid Max.Temperature

          Integrated type

          70 deg.C

          Separated type

          Poly Neoprene Lining

          80 deg.C;120 deg.C(notes in order)

          Polyurethane Lining

          80 deg.C

          PTFE Lining

          100 deg.C;150 deg.C(notes in order)

          FEP Teflon

          PFA with net

          Material of signal electrode and ground electrode

          SS316L,HastelloyB,HastelloyC,Ti,Ta,Platinum-iridium alloy,Stainless steel coating with tungsten carbide

          Electrode drawknife apparatus

          DN80~DN3000

          Connection flange material

          Carbon steel

          Connection ring material

          Stainless steel1Cr18Ni9Ti

          Enclosure protection

          ND15~DN3000 separated sensor with rubber or PU lining

          IP65 or IP68

          Integrated(rounded converter)

          IP65

          Other sensors and separated converter

          IP65

          Explosion proof sensor and converter

          IP65

          Spacing(separated type)

          Normally the separation distance between converter and sensor is less than 100m,if more please order specially.(Note: our company provide 10m length standardly,if need more, please indicate the length in order, and the cost will be add more)

          Output of analog current

          0~10mA     load resistance 0~1.5Ω

          4~20mA     load resistance 0~750Ω

          Frenquency output

          1~5000Hz

          Pulse output

          Separated type output by two way: forward and reverse flow; integrated type output one way

          Frenquency range:0~5KHz,uper limit 1~5 optionally

          Square wave or pulse with 25ms pulse width

          Transistor switch output with isolation protection,can absorb 250mA current and withstanding 35V voltage

          Two-path alarm output

          Alarmable(programable)high/low flow,blank pipe,fault condition,forward and reverse flow,simulation volume exceeds range,pulse volume exceeds range,disconnect pulse small signal

          Transistor switch output with isolation protection,can absorb 250mA current and withstanding 35V voltage(Not isolated with pulse output)

          Digital communications

          RS232,RS485,HART(add specially)

          Explosion proof mark

          Integration ExdeiaⅡCT4

          Separated Exd[ia] ⅡCT4(converter)     ExdeiaⅡCT4(sensor)

          [Type Selection]

           

          CHENGFENG FLOWMETER from factory has been committed to flow meter for decades and the research and development and production of the material level meter, over the years, we sell not only products, but also a kind of attitude and service, pay attention to is the feeling of the customer experience, from the perspective of customers, strive to achieve consistent perfect pre-sale and after-sale!

          CHENGFENG FLOWMETER  for flowmeter market customer demand, carry on the improvement of professional products, technology research and development, and strive to make customer satisfaction of the flowmeter.CHENGFENG FLOWMETER  variety, style complete, direct manufacturers, quality assurance, affordable, welcome customers to come to consult, the choose and buy.Changzhou into feng help selection, solve your doubt flowmeter.



          ? 2012 Changzhou Chengfeng Flowmeter Co.,Ltd All Rights Reserved   Main Products:Electromagnetic Flow meter  Metal Tube Flow Meter  Glass Tube flow Meter
          Design by Lingdong Internet  Switchboard:86-519-85503558,86-519-85503688  Fax:86-519-85505269,86-519-85503588-8008
          Friendly Links:成豐儀表阿里巴巴店鋪    新浪    
          主站蜘蛛池模板: 国产精品无需播放器在线播放| 国产视频一区二区三区四区视频| 亚洲国产日韩精品乱码教育| 无码人妻丝袜| 亚洲精品成人自拍视频| 亚洲色成人一区二区三区人人澡人人妻人人爽人人蜜桃麻豆 | 日韩亚洲制服丝袜中文字幕 | 欧美日韩v中文在线| 精品国产亚洲一区二区在线3d| av新版天堂在线观看| 国产成人a亚洲精品久久久久| 亚洲欧美国产另类首页| 免费看成人毛片无码视频| 97香蕉久久国产超碰青草专区| 潮喷视频在线播放| 亚洲一区无码精品色| 久久亚洲精品中文字幕馆| 天天爽夜夜爽人人爽曰| 精品国产亚洲午夜精品av| 中文字幕有码人妻在线| 久久99亚洲综合精品首页| 欧美福利电影A在线播放| 亚洲最大的成人网| 亚洲人妻乱| 97国产在线看片免费人成视频 | 亚洲一区不卡在线导航| 亚洲成人Aⅴ| 亚洲午夜理论无码电影| 欧美va| 丰满人妻一区-日韩不卡-一区二区三区| 国产精品无码2021在线观看| 狠狠色综合网站久久久久久久| 性XXXX视频播放免费直播| 亚洲AV无码乱码在线观看性色扶| 一区二区三区在线观看| 亚洲人成电影在线天堂色| 国产精品综合一区二区三区| 亚洲综合欧美日韩| 国产在线观看福利一区二区| 在线播放亚洲人成电影| 亚洲精品国产综合麻豆久久99 |